KHACHMAZ REN: STABILITY IS MUCH MORE INCREASED

Image

At the moment of generating capacity and the capacity of existing and newly created, produced one of the most important issues in the delivery of electricity to consumers in a timely and quality. Transmission lines and substations in addressing this issue plays an important role in normal function. For this purpose, as well as other objects in the northern region, which plays an important role in energy "Xachmaz REN" traditional reconstruction and repair work is carried out.

According to the information given by mentioned enterprise to the Press – release of "Azerenergy" JSC, During the last three months of last year, a number of items relating to current and overhaul of the company were held successfully. Actions carried out among the 110 kV "Guba", "Rehimli", "Shabran " and other plants for the repair of vacuum circuit breakers , transformers, oil circuit breaker replaced logging , testing , measuring, checking , etc. carried relaying circuits . for various purposes , including work carried out . At the same time, the "good " S over 10 km fitted into the socket of a new two-loop "Aygunlu" and " Shahnazarli " TL shot. It should be noted that similar repairs 35 kV "Guba ", " Alpan " and "Nugadi" with (S\S) is also provided .

Other projects in the enterprise source told him that the new 35 kV "Tangaalti", "(TL) shooting continued Gechresh ' s completed relevant overhead power lines . At the same time , 110 kV , " Guba " with the new distribution system 35 kV laid the foundation was laid and cable channels . Incidentally, the 110 kV " Shabran " , "good ", " new oil vacuum circuit breakers type Pirabadil ' with the changing perspective on the development of " licking YS- 16 MVA " separates the butt type of switch number 1 replacement , construction of a new reservoir and back fat , YS- 16 MVA " Khudat 'in type switch number 1 to replace the transition that separates the first and second section is intended to change the current transformers and tear.

Repair work , 330, 110 and 35 kV overhead lines from touched . Thus, the term " Derbend " I , VIII " Khachmaz ", " Charkhi ", " Khudat Yalama ", " Lip - Hussar" "Channel" and more than 400 other TL generally insulators have been replaced by new ones.

In addition to all these studies, substation directions appropriate fire safety measures have been implemented . Thus, eliminating the power transformer oil spills , pools of water filled with water and other necessary security measures undertaken .

Finally, it should be noted that the reconstruction of power facilities to the existing climatic conditions , consumers are more stable and efficient energy.